27/03/2025 14:04:55 : Created file: C:\Users\promerogomb\Desktop\fluxcontrol\motores\PLACond\MessageLogs\messageLog_10216.txt 27/03/2025 14:04:55 : Loaded file: C:\Users\promerogomb\Desktop\fluxcontrol\motores\PLACond.mot 27/03/2025 14:04:56 : pymotorcad: ShowMagneticContext 27/03/2025 14:04:56 : pymotorcad: SetVariable ShaftSpeed = 3000 27/03/2025 14:04:56 : pymotorcad: SetVariable CurrentDefinition = 1 27/03/2025 14:04:56 : pymotorcad: SetVariable RMSCurrent = 3 27/03/2025 14:04:56 : pymotorcad: SetVariable DCBusVoltage = 350 27/03/2025 14:04:56 : pymotorcad: SetVariable PhaseAdvance = 45 27/03/2025 14:04:56 : pymotorcad: SetVariable MagneticThermalCoupling = 0 27/03/2025 14:04:56 : pymotorcad: ImportSolidMaterial PLACond 27/03/2025 14:04:56 : No solids found in solid database file c:\ANSYS_Motor-CAD\2024_1_3\Motor-CAD Data\materials\solids.mdb Please check you have selected the correct file. 27/03/2025 14:04:56 : pymotorcad: SetVariable BackEMFCalculation = False 27/03/2025 14:04:56 : pymotorcad: SetVariable CoggingTorqueCalculation = False 27/03/2025 14:04:56 : pymotorcad: SetVariable ElectromagneticForcesCalc_OC = False 27/03/2025 14:04:56 : pymotorcad: SetVariable TorqueSpeedCalculation = False 27/03/2025 14:04:56 : pymotorcad: SetVariable DemagnetizationCalc = False 27/03/2025 14:04:56 : pymotorcad: SetVariable ElectromagneticForcesCalc_Load = False 27/03/2025 14:04:56 : pymotorcad: SetVariable InductanceCalc = False 27/03/2025 14:04:56 : pymotorcad: SetVariable BPMShortCircuitCalc = False 27/03/2025 14:04:56 : pymotorcad: SetVariable TorqueCalculation = True 27/03/2025 14:04:56 : pymotorcad: GetVariable SHAFTSPEED = 3000 27/03/2025 14:04:56 : pymotorcad: GetVariable CURRENTDEFINITION = 1 27/03/2025 14:04:56 : pymotorcad: GetVariable PEAKCURRENT = 4,24264068711929 27/03/2025 14:04:56 : pymotorcad: GetVariable TORQUECALCULATION = True 27/03/2025 14:04:56 : pymotorcad: DoMagneticCalculation 27/03/2025 14:04:57 : Status: Solving FEA model 27/03/2025 14:04:58 : Q axis current only Point Calculation 27/03/2025 14:04:58 : Solving FEA model 27/03/2025 14:04:58 : Load Point Calculation 27/03/2025 14:04:58 : Solving FEA model 27/03/2025 14:04:59 : Solving FEA model 27/03/2025 14:04:59 : Transient Torque Calculation 27/03/2025 14:04:59 : Solving FEA model 27/03/2025 14:05:08 : FEA Calculation Time: 10 Seconds 27/03/2025 14:05:08 : Creating folder: C:\Users\promerogomb\Desktop\fluxcontrol\motores\PLACond\FEResultsData\feasys\ 27/03/2025 14:05:08 : Warning: Operating point outside voltage limit. Check the DC bus voltage. 27/03/2025 14:05:08 : Solving completed 27/03/2025 14:05:08 : Nodes count = 3365 27/03/2025 14:05:08 : Elements count = 6472 27/03/2025 14:05:08 : Status: Solving Completed 27/03/2025 14:05:08 : pymotorcad: ExportResults 27/03/2025 14:05:08 : pymotorcad: Quit